Bullet Points APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black
Each of several items in a list, preceded by a bullet symbol for emphasis. For easy access to this data, refer to the "BulletPoints" tag in XML or JSON.
:
- - Metered 0U Black
- - 20 AC outlet(s) C13 coupler, C19 coupler
- - 3680 W
Warranty:
2 years
Long product name APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black
:
The long product name of APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black. For easy access to this data, refer to the "ProductDescription" block and the "ShortDesc" tag in XML or the "Description" block and the "LongProductName" tag in JSON.
Rack PDU 2G, Metered, ZeroU, 20A/208V, 16A/230V, (18) C13 & (2) C19
More>>>
APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black:
The official description of APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black as supplied by the manufacturer. For easy access to this data, refer to the "ProductDescription" block and the "LongDesc" tag in XML or the "Description" block and the "LongDesc" tag in JSON.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Short summary description APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black:
This short summary of the APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black data-sheet is auto-generated and uses the product title and the first six key specs.
APC AP8858, Metered, 0U, Vertical, Black, 20 AC outlet(s), C13 coupler, C19 coupler
Long summary description APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black:
This is an auto-generated long summary of APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black based on the first three specs of the first five spec groups.
APC AP8858. PDU types: Metered, Rack capacity: 0U, Mounting: Vertical. AC outlets quantity: 20 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Input connection type: IEC-320 C20. Certification: CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH. Monitoring: Current, Power, Voltage. Nominal input voltage: 230 V, AC input frequency: 50 - 60 Hz, Load capacity: 3680 VA