- Brand : Tripp Lite
- Product name : 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA
- Product code : PDU3EVN6L2130
- GTIN (EAN/UPC) : 0037332195296
- Category : Power Distribution Units (PDUs)
- Data-sheet quality : created/standardized by Icecat
- Product views : 77746
- Info modified on : 10 Aug 2024 11:42:45
- Warranty: : 2-year limited warranty
-
Long product name Tripp Lite 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA
:
8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA
-
Tripp Lite 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA
:
The PDU3EVN6L2130 8.6kW 3-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. Recommended for IT and industrial applications, it features 45 outlets—36 C13 (208V), 6 C19 (208V) and 3 NEMA 5-15/20R (120V)—with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A six-foot cord with NEMA L21-30P input plug connects the 3-phase PDU to a compatible AC power source, generator or protected UPS.
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A color touchscreen LCD lets you toggle between menus to monitor input current level per phase and output current per load bank with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the PDU through a mobile device.
The 0U PDU mounts vertically in racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access. -
Short summary description Tripp Lite 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA
:
Tripp Lite 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA, Monitored, 0U, Three-phase, Vertical, Metal, Black, Grey
-
Long summary description Tripp Lite 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA
:
Tripp Lite 8.6kW 3-Phase Monitored PDU, LX Interface, 208/120V Outlets (36 C13/6 C19/3 5-15/20R), LCD, NEMA L21-30P, 1.8m/6 ft. Cord, 0U 1.8m/70in. Height, TAA. PDU types: Monitored, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 45 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, NEMA 5–15R, NEMA 5–20R, Power plug: NEMA L21-30P. Cable length: 1.8 m. Supported network protocols: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP. Nominal input voltage: 208 V, Maximum current: 24 A, AC input frequency: 50 - 60 Hz
Design | |
---|---|
PDU types | Monitored |
Type | Three-phase |
Rack capacity | 0U |
Mounting | Vertical |
Housing material | Metal |
Product colour | Black, Grey |
Display | LCD |
Ports & interfaces | |
---|---|
AC outlets quantity | 45 AC outlet(s) |
Power plug | NEMA L21-30P |
AC outlet types | C13 coupler, C19 coupler, NEMA 5–15R, NEMA 5–20R |
Features | |
---|---|
Cable length | 1.8 m |
Management features | |
---|---|
Supported network protocols | IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP |
Power | |
---|---|
Nominal input voltage | 208 V |
AC input frequency | 50 - 60 Hz |
Maximum current | 24 A |
Nominal output voltage | 120-208 V |
Maximum power | 8600 W |
Weight & dimensions | |
---|---|
Width | 55.1 mm |
Weight & dimensions | |
---|---|
Depth | 64 mm |
Dimensions (WxDxH) | 55 x 64 x 1778 mm |
Height | 1778 mm |
Weight | 6.12 kg |
Packaging data | |
---|---|
Package weight | 8.05 kg |
Package width | 245.1 mm |
Package depth | 1927.1 mm |
Package height | 180.1 mm |
Packaging content | |
---|---|
Manual |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 50 °C |
Storage temperature (T-T) | -15 - 60 °C |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3000 m |
Technical details | |
---|---|
Compliance certificates | RoHS |
Logistics data | |
---|---|
Country of origin | Taiwan |
Products per master (outer) case | 1 pc(s) |
Country | Distributor |
---|---|
|
1 distributor(s) |